CHAPTER 3
Operations at the Application Level
89
Phone: 06641111111
Key: 123456789
Start: Fri May 5 11:44:38 2006
Duration: 15
OK
HANGUP
DESCRIPTION hang up call to device
P
ARAMETERS Device ID and shared secret
R
ETURNS A list of status parameters. The list is self-explanatory.
R
EMARKS The shared secret is needed to hangup the call.
E
XAMPLE hangup 26127 123456789
Dev: 26127
Modem: external
Phone: 06641111111
Start: Fri May 5 11:44:38 2006
Duration: 38
OK
MDMSTAT
DESCRIPTION Display modem state
P
ARAMETERS None.
R
ETURNS A list of current status parameters. The list is self-explanatory.
R
EMARKS Get only.
E
XAMPLE mdmstat
Dev: 0
Modem:
Phone:
OK
CALLJOURNAL
DESCRIPTION Display the call journal.
P
ARAMETERS None.
R
ETURNS List of calls in the call journal. The list is self-explanatory.