Adcon A720 Guide de l'utilisateur Page 80

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 146
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 79
CHAPTER 3
Advanced Functions
80
REMARKS None.
UPTIME
DESCRIPTION Returns the amount of time the A440 Wireless Modem connected
to the gateway has been operational.
P
ARAMETERS None.
R
ETURNS The amount of time the wireless modem has been in operation.
R
EMARKS None.
E
XAMPLE uptime
Up 230 day(s), 10 hour(s), 14 minute(s)
OK
NOP
This command is deprecated in emu3ap. It has been included for
compatibility purposes, but always returns OK. The A840
Telemetry Gateway’s software is stored in its internal Flash
EEPROM.
HELP
DESCRIPTION Returns all the available commands in the emu3ap software.
P
ARAMETERS None.
R
ETURNS A list of commands.
QUIT
DESCRIPTION Exits the emu3ap software. If you were logged in as the user adv,
you will be returned to the Linux login prompt. Otherwise, you will
be returned to a Linux shell.
P
ARAMETERS None.
R
ETURNS Nothing.
R
EMARKS You can use the EXIT command with the same result.
TIME
DESCRIPTION Command to determine the current systemtime.
P
ARAMETERS None.
Vue de la page 79